Example only. The customer, installer, address, meter number, products, references and figures are invented.
Sample dossier: 4 kWp solar, 3.68 kW inverter, single phase
1. Job summary
- Installer
- Example Solar Ltd (invented), 2 Sample Yard, Exampleton, ZZ1 1ZZ
- Customer
- Alex Example, 1 Example Street, Exampleton, ZZ1 1ZZ
- MPAN
- 10 0000 0000 000
- System
- 10 modules of 400 W (4.0 kWp), one 3.68 kW single phase inverter, no storage
- Filing
- G98: 3.68 kW on one phase is 16 A, within the limit
- Commissioned
- 12 January 2027
- Due 8 February 2027
- Network operator: G98 notification or G99 installation document
- Due 26 January 2027
- MCS certificate, current scheme (weekends excluded, check bank holidays)
2. What we found before you file
| Finding | What to do |
|---|---|
| The diagram shows an inverter model ending "-A"; the datasheet sent ends "-B". | Confirm the installed model. The type test reference must match it. |
| No photo shows the cut-out fuse rating. | Send a photo where the rating can be read. |
| The location of the isolator is not recorded. | Tell us where it is; the form asks for it. |
3. G98 commissioning notification: values for Form B
You receive these entered on the current official form, ready to check and sign.
- Customer and contact
- Alex Example, 01632 960123, alex@example.com
- Installer and accreditation
- Example Solar Ltd, certification number EXAMPLE-000, contact Sam Sample, 01632 960456
- Installation address
- 1 Example Street, Exampleton, ZZ1 1ZZ
- Location of unit and isolator
- Unit in the loft; lockable isolator: to be confirmed
- Generating unit
- Example Inverters (invented), model EX-3680-B, photovoltaic, installed 12 January 2027
- Type test register reference
- EXAMPLE-0001
- Registered capacity
- 3.68 kW on one phase; storage: none
- Attachments
- System schematic (also left at the meter position), cut-out photo
- Declaration and signatures
- Left for you to sign
4. MCS database data sheet
- Contract and commissioning dates
- 2 December 2026; 12 January 2027
- Technology and project type
- Solar PV, domestic, retrofit
- Technical supervisor
- Sam Sample
- Total cost including VAT
- £6,000 (example)
- Grant or incentive
- None
- Products
- 10 × Example Modules EX-400; 1 × Example Inverters EX-3680-B; pitched roof kit EX-ROOF
- Total installed and declared net capacity
- 4.0 kWp; 3.68 kW
- Estimated annual generation
- 3,400 kWh (example value; in a real job it comes from your performance estimate)
- Planning and building regulations routes
- As you declare them
- Grid connection type
- On grid, G98
- Generation meter
- Example Meters EM-1, serial 000000, reading 0 kWh
- Consumer details and financial protection provider
- As above; provider as you declare it
5. Customer handover pack: contents
| Document | Comes from |
|---|---|
| Summary: client, site, contractor, key components, performance estimate, recommended first periodic inspection, MCS contacts, declaration to sign | We prepare it; you sign |
| Commissioning forms and checklists | Your readings, laid out by us |
| Maintenance: what the owner checks, how often, and what to do about a problem; services you offer | We draft it; you approve |
| Network operator notification | Section 3, signed |
| User manuals and warranties | You send them |
| Incentive scheme documents, if any | You send them |
| MCS certificate | You raise it; add it to the pack |
Example only. Do not file any value on this page.